← Back to Blog
midi monitormidi troubleshootingmidi messages

MIDI Monitor Guide: How to See What Your MIDI Controller Is Sending

By MidiMacro Team Published

When a MIDI setup doesn’t work, guessing is slow. Is the controller sending anything? Is it on the wrong channel? Is the knob sending CC 7 when your synth expects CC 74? A MIDI monitor answers all of these in seconds, because it shows every message as it arrives.

This guide explains how to read a MIDI monitor, how to decode raw MIDI bytes, and how to use it to fix the most common MIDI problems.

What a MIDI Monitor Shows

A MIDI monitor (also called a MIDI console or MIDI logger) lists incoming messages in real time. A good one shows:

  • The device the message came from
  • The message type, such as Note On, Control Change or Pitch Bend, plus its channel
  • The values, such as note number and velocity, or controller number and value
  • The raw bytes, for when you need to know exactly what was sent
  • Timing: when it arrived and how long after the previous message

The MIDI console in MidiMacro shows all of these, color-coded per device. It also shows where each message was sent to by your routing, which makes it a routing debugger as well as a monitor. You can pause it, clear it, or filter it to a single device.

A Quick Guide to MIDI Messages

Most MIDI 1.0 messages are 2 or 3 bytes. The first byte (the status byte) says what kind of message it is and which of the 16 channels it’s on. The bytes after it carry the values, from 0 to 127.

Status byte (hex)MessageData bytesTypical source
8nNote Offnote, release velocityReleasing a key or pad
9nNote Onnote, velocity (0 = off)Pressing a key or pad
AnPolyphonic Aftertouchnote, pressurePressing harder on one key (rare)
BnControl Change (CC)controller number, valueKnobs, faders, buttons, sustain pedal, mod wheel
CnProgram Changeprogram numberPatch select buttons
DnChannel AftertouchpressurePressing harder on held keys
EnPitch BendLSB, MSB (14-bit)Pitch wheel
F0–FFSystem messagesvariesSysEx, clock, start/stop

The n is the channel: 0 to F in hex, which is channel 1 to 16 in the numbering musicians use. So 90 3C 64 means Note On, channel 1, note 60 (middle C), velocity 100, and B1 4A 7F means CC 74 on channel 2, value 127.

Common CC numbers worth knowing

  • CC 1: Mod wheel
  • CC 7: Channel volume
  • CC 10: Pan
  • CC 11: Expression
  • CC 64: Sustain pedal (0–63 off, 64–127 on)
  • CC 74: Often filter cutoff/brightness

Troubleshooting MIDI with a Monitor

”My controller does nothing”

Open the monitor and press a key.

  • Nothing appears: the computer isn’t receiving MIDI from that device. Check the cable and USB port, make sure the controller is powered and in its normal MIDI mode, and close other apps. On Windows, older drivers only allow one app to open a device at a time (see routing MIDI on Windows).
  • Messages appear: the controller is fine. The problem is between the computer and the destination app: the wrong input selected, the wrong channel, or a routing issue.

”It plays, but on the wrong sound”

Look at the channel in the monitor. If your controller sends on channel 2 and your synth only listens on channel 1, notes are ignored. Either change the controller’s channel, set the synth to “omni”/all channels, or remap the channel along the way with MIDI mapping software.

”The knob doesn’t control the parameter”

Turn the knob and note which CC number it sends. Compare it with what the synth or plugin expects (check its manual or MIDI implementation chart), then either use the app’s MIDI learn or remap the CC number in your router.

”Notes get stuck”

Look for Note On messages without a matching Note Off (or Note On with velocity 0). Missing note-offs usually mean a MIDI loop, a cable dropout, or a routing change in the middle of a held note. If you see every message appear twice, you probably have a loop: an app sending MIDI back into an input it listens to.

”The sustain pedal works backwards”

Press and release the pedal and watch CC 64. If you see 127 when the pedal is up and 0 when it’s down, the pedal’s polarity doesn’t match the keyboard. Many keyboards detect polarity at power-on, so plug the pedal in before switching on, without pressing it. Otherwise, use a polarity switch on the pedal or invert the values with a mapper.

”The monitor is flooded with messages”

A steady stream of system messages, often 24 per quarter note, is MIDI clock from a drum machine, sequencer or DAW sync. Some devices also send Active Sensing every few hundred milliseconds. Turn clock output off on the sending device if you don’t need it, or filter the monitor to the device you’re testing.

”My macro fires twice”

Press the pad and look at the monitor. Most pads send two messages: one on press and one on release. Make your macro match only the press, for example a velocity range of 1–127 for Note On. See MIDI to macro for details.

From Monitoring to Doing Something

Once you can see what your controller sends, you can put it to work. In MidiMacro, click Assign Macro on any message in the console to turn it into a keyboard shortcut, or open the Route editor to send it to other devices and apps. That’s why we built the monitor into the same window: the step after “what does this button send?” is almost always “now make it do something.”

Get Started

MidiMacro combines a MIDI monitor, a visual MIDI router and MIDI to keyboard macros, for Windows, macOS and Linux, with a one-time price. Check the features and the FAQ, or read our guide to MIDI routing software.

Ready to Supercharge Your Workflow?

Join us and transform your MIDI devices into powerful productivity tools.

One-time payment • Lifetime access • Free updates